Robust Generator Maintenance Schedule for Frequency-Secure Power Systems
Yang Yang, Qiuzhuang Sun, Jimmy Chih‐Hsien Peng, Loon Ching Tang, Zhi‐Sheng Ye
Manufacturing & Service Operations Management
인용
- 주제녹색기술 정책 · 생산·최적화
- 방법
- 현상
Problem definition: Normal operations of a power system require that alternating current frequency be maintained at a nominal value, for example, 50 Hz, whereas severe deviation from this value due to power deficiencies can cause cascading generator trips. Maintaining the frequency requires adequate inertia and frequency regulation reserve, which are primarily provided by online generators. In daily operations, generators due for preventive maintenance must be taken offline, and thus an improper maintenance schedule could jeopardize frequency security, as exemplified by the recent Texas power blackout. However, this natural nexus between frequency security and maintenance has been overlooked largely in the literature. Methodology/results: We fill the gap by developing a long-term generator maintenance scheduling model that incorporates frequency security constraints with hourly fidelity to meet industrial standards. These constraints amount to scheduling adequate inertia and frequency regulation reserve by considering uncertain power deficiency and inertia from intermittent renewable energy. We hedge the uncertainties by employing a robust optimization approach in which historical data are used to construct ambiguity sets. This inevitably results in an ultra-large-scale robust model because of the hourly fidelity. We reformulate it as a large-scale, mixed-integer linear program. An algorithm based on the progressive hedging idea is proposed to decompose the model into subprograms that can be solved in parallel. An explicit-dual cutting-plane method for the subprograms and a novel lower bound for the model are developed to accelerate computation in each iteration. Compared with the standard progressive hedging algorithm and an L-shaped algorithm with strengthened Benders cuts, our algorithm is approximately 10 times faster and avoids the out-of-memory issues encountered by these benchmarks. Managerial implications: Integrating frequency security enforces generator maintenance to distribute more evenly across the planning horizon. This leads to a more stable maintenance crew size and a significant reduction in out-of-sample costs in our simulation using real data. Additionally, our study reveals that inertia is crucial for frequency security and that low-cost inertia resources like synchronous condensers can enhance frequency security. Funding: The research was conducted at the University of Macau, supported by the UM Grant SRG2025-00044-IOTSC and by FDCT support 001/2024/SKL (Y. Yang). This research was supported by the National Science Foundation of China 72471144 (Q. Sun). This research was supported by Singapore MOE AcRF Tier 2 Grant [A-8001052-00-00, A-8002472-00-00] (Z. Ye). The research was conducted at the Future Resilient Systems at the Singapore-ETH Centre, which was established collaboratively between ETH Zurich and the National Research Foundation Singapore. This research is supported by the National Research Foundation Singapore (NRF) under its Campus for Research Excellence and Technological Enterprise (CREATE) programme (J.C.-H. Peng, L.C. Tang, Z. Ye). Supplemental Material: The online appendix is available at https://doi.org/10.1287/msom.2023.0664 .
불러오는 중…
- Reliable Frequency Regulation Through Vehicle-to-Grid: Encoding Legislation with Robust Constraints
- Multistage Stochastic Optimization for Production‐Inventory Planning with Intermittent Renewable Energy
- Condition-Based Production for Stochastically Deteriorating Systems: Optimal Policies and Learning
- Electric Power System Planning with Explicit Stochastic Reserves Constraint
- When Should the Off-Grid Sun Shine at Night? Optimum Renewable Generation and Energy Storage Investments
- Real-Time Integrated Learning and Decision Making for Cumulative Shock Degradation
- Planning Electric Power Generation: A Nonlinear Mixed Integer Model Employing Benders Decomposition
- Maximizing the Effectiveness of a Preventive Maintenance System: An Adaptive Modeling Approach
- Tailored Benders Decomposition for a Long-Term Power Expansion Model with Short-Term Demand Response
- Adaptive Two-Stage Stochastic Programming with an Analysis on Capacity Expansion Planning Problem
아직 이 논문을 인용한 탑저널 논문이 없습니다.
15 / 44편
- Impact of Electricity Pricing Policies on Renewable Energy Investments and Carbon Emissions
- Strategic Investment in Renewable Energy Sources: The Effect of Supply Intermittency
- Curtailing Intermittent Generation in Electrical Systems
- When Shared Autonomous Electric Vehicles Meet Microgrids: Citywide Energy-Mobility Orchestration
- Tailored Benders Decomposition for a Long-Term Power Expansion Model with Short-Term Demand Response
- Optimizing Day-Ahead Electricity Market Prices: Increasing the Total Surplus for Energy Exchange Istanbul
- 탑저널 밖 논문
- 탑저널 밖 논문
- 탑저널 밖 논문
- 탑저널 밖 논문
- 탑저널 밖 논문
- 탑저널 밖 논문
- 탑저널 밖 논문
- 탑저널 밖 논문
- 탑저널 밖 논문
- 저널Manufacturing & Service Operations Management · 28(4) · 1172–1191
- 토픽Power System Reliability and Maintenance · Safety, Risk, Reliability and Quality
- DOI10.1287/msom.2023.0664
- 저자Yang Yang, Qiuzhuang Sun, Jimmy Chih‐Hsien Peng, Loon Ching Tang, Zhi‐Sheng Ye